IRD DMFC31M0210

The Direct Methanol Fuel Cell Stack (DMFC) consists of 31 Cell Units electrically connected in series. Each Cell Unit is supplied with methanol and air through a gas/liquid manifold. Each Cell Unit consists of a bipolar flow plate and a MEA. The MEA is the active electrochemical cell consisting of a methanol electrode, a polymer electrolyte and an air electrode with 180 cm2 in active area.

Electrical Output

Stack Power, nominal

0.50 kW

Stack Power, max

0.70 kW

Stack Current

40 A

Stack Voltage

13 V

Stack Power efficiency

34 %

Heat

Heat, PW [LHV]

 0.85 kW

Mechanical

Number of Cells

31

Stack Dimensions (excl. connectors)

265 mm x 184 mm x 184 mm

Stack Weight

~ 8.1 kg

Supply

 

Range

Nominal

Fuel Supply

0.5-2.0 M Methanol

1.0 M Methanol

lambda-Air

2.0-5.0

3.0

lambda-Methan

3.0-12.0

6.0

Operating temperature

10-75 °C

75 °C

Air flow

40-200 L/min

65 L/min

Fuel flow

0.05-2.5 L/min

0.78 L/min

Consumption

Water Consumption rate

3.07 g/min

Methanol Consumption rate

 6.89 g/min

Air Consumption rate

 

Environmental Conditions

Operating Temperature Range

10-90 ºC

Humidity (RH)

0-90 %