The Direct Methanol Fuel Cell Stack (DMFC) consists of 15 Cell Units electrically connected in series. Each Cell Unit is supplied with methanol and air through a gas/liquid manifold. Each Cell Unit consists of a bipolar flow plate and a MEA. The MEA is the active electrochemical cell consisting of a methanol electrode, a polymer electrolyte and an air electrode with 90 cm2 in active area.

Electrical Output

Stack Power, nominal

100 Watt

Stack Power, max

150 Watt

Stack Current

18 Ampere

Stack Voltage

6 Volt

Stack Power efficiency

35 %

Heat

Heat, PW [LHV]

220 Watt

Mechanical

Number of Cells

15

Stack Dimensions (excl. connectors)

145 mm x 145 mm x 163.5 mm

Stack Weight

~ 4 kg

Supply

 

Range

Nominal

Fuel Supply

0.5-2.0 M Methanol

1.0 M Methanol

Lambda-Air

2.0-5.0

3.0

Lambda-Methanol

3.0-12.0

6.0

Operating temperature

10-75 °C

75 °C

Air flow

8-50 L/min

15 L/min

Fuel flow

0.03-0.75 L/min

0.17 L/min

Consumption

Water Consumption rate

0.032 kg/h

Methanol Consumption rate

0.07 l/h

Air Consumption rate

270 l/h [0.27 Nm 3 /hour]

Environmental Conditions

Operating Temperature Range

10-90 ºC

Humidity (RH)

0-90 %