IRD DMFC15M0321The Direct Methanol Fuel Cell Stack (DMFC) consists of 15 Cell Units electrically connected in series. Each Cell Unit is supplied with methanol and air through a gas/liquid manifold. Each Cell Unit consists of a bipolar flow plate and a MEA. The MEA is the active electrochemical cell consisting of a methanol electrode, a polymer electrolyte and an air electrode with 90 cm2 in active area.
|
Electrical Output
|
|
Stack Power, nominal
|
100 Watt
|
|
Stack Power, max
|
150 Watt
|
|
Stack Current
|
18 Ampere
|
|
Stack Voltage
|
6 Volt
|
|
Stack Power efficiency
|
35 %
|
|
Heat
|
|
Heat, PW [LHV]
|
220 Watt
|
|
Mechanical
|
|
Number of Cells
|
15
|
|
Stack Dimensions (excl. connectors)
|
145 mm x 145 mm x 163.5 mm
|
|
Stack Weight
|
~ 4 kg
|
|
Supply
|
|
|
Range
|
Nominal
|
|
Fuel Supply
|
0.5-2.0 M Methanol
|
1.0 M Methanol
|
|
Lambda-Air
|
2.0-5.0
|
3.0
|
|
Lambda-Methanol
|
3.0-12.0
|
6.0
|
|
Operating temperature
|
10-75 °C
|
75 °C
|
|
Air flow
|
8-50 L/min
|
15 L/min
|
|
Fuel flow
|
0.03-0.75 L/min
|
0.17 L/min
|
|
Consumption
|
|
Water Consumption rate
|
0.032 kg/h
|
|
Methanol Consumption rate
|
0.07 l/h
|
|
Air Consumption rate
|
270 l/h [0.27 Nm 3 /hour]
|
|
Environmental Conditions
|
|
Operating
Temperature
Range
|
10-90 ºC
|
|
Humidity (RH)
|
0-90 %
|
|